releu cu timer si ecran display oled programabil DC 6-30V micro USB 5V
Cost unic de transport la toate comenzile acestui vanzator
-
Produs:Nou, Fără garanție
-
Numar articol:202934856
-
Disponibilitate:Indisponibil
-
Preț:55,00 Lei
-
Anuntul a expirat la:06.03.2022, 08:15
-
Ai o nelamurire?
-
Vandut de:
-
Vinde si tu:Pune in vanzare un produs ca acesta
-
Optiuni:
Descriere
Vânzatorul este direct răspunzator pentru produsul afișat în această pagină.
Disponibilitate: Indisponibil - Vezi produse similare
Specificatii
Feature:
1.Parameters can be
modified via UART
2.Stop button to
provide emergency stop function
3.OP/CL/LOP params
can be modified individually
4.All parameters are
automatically saved by power off
5.Display with LCD
two columns,Can display parameters
directly
6.Trigger mode: high
and low level,switch quantity.meet most of the
needs
7.5 minutes without
any operation into a low-power state.Any action wake
up
8.Optocoupler
isolation,Strong anti-interference ability, Industrial grade
circuit board
Timing
Range
9.Power
supply:6~30V,also supports micro USB 5.0V,very convenient.Anti back
connection of power supply
Specifications:
Power Supply: 6V~30V
and micro USB 5.0 V
Trigger signal
source: High level(3.0V~24.0V),Low level(0.0V ~0.2V),Switch
signal.
Maxmum Output load:
DC 30V 5A and AC 220V 5A
Static Current: 15mA
Operating current: 50mA
Service life: more
than 100,000 times; working temperature:
-40-85°C:
Working Mode
Introduction(P1~P7)
P1: After the signal
is triggered, the relay conduction in OP time then disconnects; In
the OP time, the signal is invalid.
P2: After the signal
is triggered, the relay conduction in OP time then disconnects; In
the OP time, the signal triggers a new
timer.
P3: After the signal
is triggered, the relay conduction in OP time then disconnects; In
the OP time, signal trigger reset timer,relay disconnected and stop
timing.
P4: When triggered,
After the relay is disconnected from CL time, relay conduction OP
time, after timing is complete, disconnect
relay.
P5: When triggered,
After the relay conduction op time, the relay disconnects the CL
time, and then loops the above action, gives the signal again in
the loop, relays disconnect, stops the timer, and the number of
cycles (LOP) can be set;
P6: When triggered,
After the relay conduction op time, the relay disconnects the CL
time, and then loops the above action, signal is invalid in the
loop, the number of cycles (LOP) can be
set;
P7: Signal hold
function: The signal is maintained, the timing is cleared, and the
relay conduction; when the signal disappears, the relay disconnects
after the timing OP; during the timing, there is another signal and
the timing is cleared;
Timing
Range:
0.01 sec~9999
min
How to choose the
timing range:
In the OP/CL
parameter modification interface, press the STOP button shortly to
select the timing range.
XXXX Timing
range:1sec~9999sec
XXX.X Timing
range:0.1sec~999.9sec
XX.XX Timing
range:0.01sec~99.99sec
X.X.X.X Timing
range:1min~999.9min
For example, if you
want to set the OP to 3.2 seconds, move the decimal point to ten
digits. LCD display 003.2
Parameter
Description: OP on-time, CL off time, LOP cycle times (1 - 9999
times, "----" represents an infinite number of
cycles)
Parameter
Settings:
a)Press and hold the
SET key to enter the setting interface;
b)First set the
working mode, work mode flashes reminder, set the working mode by
pressing the UP / DOWN keys;
c)Short press the SET
button to select the working mode and enter the system parameter
settings.
d)In the system
parameter setting interface, press SET key to switch the system
parameters to be modified, and press / long press UP/DOWN key to
modify. (Note: Short press SET in P-1~P-3, P-7 mode is
invalid);
e)In the OP/CL
parameter modification interface, short press STOP to switch the
timer unit (1s/0.1s/0.01s/1min);
f)After all
parameters are set, press and hold the SET button for more than 2
seconds to release the hand, save the parameter settings and exit
the setting interface
Additional
features:
a)Low-power state: In
the running interface, by pressing the STOP button for a long time,
the Low-power function is started or closed (L-P selects on to
start the hibernation function, and off turns off the hibernation
function);
b)Relay function
selection: In the operation interface, by pressing the STOP button
shortly, the relay function is started or closed, 'on' meets the
conduction condition relay normally turns on, 'OFF' meets the
conduction condition relay does not turn on; 'OFF' In the state,
the system flashes 'OUT';
c)Parameter view: In
the operation interface, short press the SET key to display the
current parameter setting of the system, without affecting the
normal operation of the system;
d)Display content
switching: In P-5 P-6 mode, switch display content (run time/cycle
number) by pressing DOWN key momentarily
Size:8x3.8cm/3.15x1.5inch
Note:
Please allow 1-3mm
error due to manual measurement.pls make sure you do not mind
before you bid.
Due to the difference
between different monitors,the picture may not reflect the actual
color of the item.Thank you!
Package
Includes:
1x Delay Timer
Relay
Modalitati de livrare si plata
LIVRARE
In Bucuresti
-
- Predare personala in max. 24 de ore
PLATA
- - La predare
- - Ramburs
Politica de retur
- - Produsul nu se poate returna.